Newsletter
Language
Language:
 
News
Archival Issues
Volume 19, 2017
Volume 18, 2016
Volume 17, 2015
Volume 16, 2014
Volume 15, 2013
Volume 14, 2012
Volume 13, 2011
Volume 12, 2010
Volume 11, 2009
Volume 10, 2008
Volume 9, 2007
Volume 8, 2006
Volume 7, 2005
Volume 6, 2004
Volume 5, 2003
Volume 4, 2002
Volume 3, 2001
Volume 2, 2000
Volume 1, 1999
Search
 » 
Journal Abstract
 
The Treatment of Intertrochanteric Fractures of the Femur with Endovis Nail
Alessandro Geraci, Ricciardi Alberto, Rossella Mingozzi, Michele Spinelli
Ortop Traumatol Rehabil 2013; 15(6):658-658
ICID: 1091581
Article type: Editorial
IC™ Value: 2.40
Abstract provided by Publisher
 
Dear Editor,
further to the stimulating discussion between the Authors and some readers, we feel that some details about the paper we authored [1] should be clarified.
For instance, we called the analyzed system Endovis while the exact name is Endovis Bio Advanced (Endovis BA). Both devices are pertrochanteric intramedullary nails, both are manufactured by Citieffe s.r.l., but Endovis BA represents the evolution of Endovis nail (which has been no more on the market since 2008). The underlying concept design is the same for both nails; in fact, they are both equipped with two parallel cephalic screws and they both allow for distal locking. The two parallel cephalic screws are designed to control and reduce undesired side-effects such as rotational instability and femoral head “cut-off” [2]. Both are available in two different versions (Standard and Medium, Endovis BA is completed by a Long version), and have cervical-diaphyseal angulation to naturally fit the procurved femoral anatomy. Both have a distal diapason profile in order to decrease stiffness difference between the nail and the hosting bone and, consequently, avoid excessive contact stress generation.
The main differences between the two systems are represented by [3], [4]:
• Material – Endovis BA is made of titanium, whereas Endovis was made of stainless steel.
• Cephalic screws – in Endovis BA they have the same diameter, whereas in Endovis they had two different diameters.
• Dimensions – Endovis BA is about 15% smaller.
Nevertheless, it must be stressed that, with Endovis BA the same key features that proved successful with Endovis were emphasized and improved with the state-of-the-art production technologies and materials. Overall, Endovis BA evolved toward higher patient tolerability while maintaining safety and improving effectiveness [5].
The study we documented in the referred paper [1] was performed using Endovis BA nail (in the period 2007-2009). Hopefully, on the basis of the additional information provided here (which is not anyhow influencing the study’s results), perspective readers will be able to adapt the issues faced in the discussion and conclusion sections to Endovis BA rather than to Endovis.


ICID 1091581

DOI 10.5604/15093492.1091581
PMID 24662913 - click here to show this article in PubMed
 
FULL TEXT 47 KB


Related articles
  • in IndexCopernicus™
         Endovis [0 related records]

  • Related articlesin PubMed database
  • in PubMed database [ related records]


  •  

    Copyright © Ortopedia Traumatologia Rehabilitacja  2017
    Page created by Index Copernicus Ltd. All Rights reserved.