Comparison Analysis of Autologous Conditioned Plasma
Radosław Lebiedziński, Andrzej Borowski, Marek Synder, Andrzej Grzegorzewski, Marek Marciniak, Marcin Sibiński
Ortop Traumatol Rehabil 2016; 18(6):563-568
ICID: 1230542
Article type: Original article
IC™ Value: 3.00
Abstract provided by Publisher
 
Background. Autologous Conditioned Plasma (ACP) has a wide range of potential uses in modern orthopaedics. The aim of this study was to examine the characteristics of proprietary ACP and compare them with those of ACP produced using a commercially available kit.
Material and methods. In the hospital laboratory, 20 samples of ACP taken from patients and prepared according to the commercially available kit protocol with a double syringe system were compared with 40 ACP preparations made using disposable sterile equipment available in the hospital.
Results. The mean platelet concentration in the ACP samples prepared according to the Arthrex protocol was 2.02 (range 1.16 to 2.64) times greater than in peripheral blood, while the concentration in the proprietary preparation was 1.61 (range 0.82 to 2.52) times higher. However, the mean platelet density in the proprietary preparation (n = 24) was 1.98 (range 1.48 to 2.52) times that of peripheral blood within 20 minutes of collection, and 1.41 (range 0.84 - 1.87) times after 20 minutes (n = 16). Therefore, the proprietary method of producing ACP is comparable to that of the commercial kit with regard to platelet density (p>0.05).
Conclusion. Using disposable hospital equipment and with a relatively short time between ACP preparation and testing, it is possible to obtain a suitable proprietary platelet-rich preparation comparable to one produced using a commercial system.

ICID 1230542

DOI 10.5604/15093492.1230542
PMID 28155835 - click here to show this article in PubMed
 
FULL TEXT 209 KB


Related articles
  • in IndexCopernicus™
         osocze bogatoczynnikowe [0 related records]
         autologous conditioned plasma [0 related records]
         platelets [23 related records]
         growth factors [17 related records]

  • Related articlesin PubMed database
  • in PubMed database [ related records]


  •  

    Copyright © Ortopedia Traumatologia Rehabilitacja  2017
    Page created by Index Copernicus Ltd. All Rights reserved.